[114] SA-1386

 

EXTERNAL TANK

MAJOR DESIGN REQUIREMENTS

STRUCTURAL

3 SIGMA LOADS AS DEFINED IN LOADS DATA BOOK

TEST TO 1.25/1.4 TIMES MAXIMUM SPECIFIED LOADS

AT LH2 TEMPERATURE FOR LH2 TANK AND ROOM TEMPERATURE FOR LO2 TANK AND INTERTANK

PROPULSION

MAINTAIN AND DELIVER PROPELLANTS TO MEET ORBITER/SSME INTERFACE REQUIREMENTS

QUALIFY BY TEST TO REQUIREMENTS

MAIN PROPULSION TESTS

THERMAL PROTECTION SYSTEM

MAINTAIN PROPELLANT QUALITY

QUALIFY BY TEST (WIND TUNNEL, COMBINED ENVIRONMENT, PLASMA ARC, ETC.) TO SPECIFIED ENVIRONMENT

THERMALLY PROTECT STRUCTURE FROM ASCENT AND PLUME INDUCED HEATING

LIMIT ICE FORMATION TO AVOID DAMAGING ORBITER

FIGURE 25
 